Customization: | Available |
---|---|
Ground Module Input Voltage: | 190V to 240V |
Ground Module Onput Voltage: | 600~800V |
Still deciding? Get samples of US$ 7503/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
items | Technical parameters | |||
Model | TPS50M-2K | TPS100M-2K | TPS150M-2K | |
Cable length | 55M | 110M | 160M | |
Ambient temperature | -20~45ºC(working),-40~65ºC(storage) | |||
Relative humidity | 10~80%RH(working),5~90%RH(storage) | |||
Altitude | ≤3000m | |||
Ground power module | Input voltage | 190~240Vac wide range input,single-phase 220Vac,frequency 50/60Hz | ||
Output voltage | 600~800Vdc adjustable,Factory Default 800Vdc | |||
Output power | ≥3500W(Rated Long-Time Output),≥4000W(peak value≮30s) | |||
take-up and payoff speed | 0~2m/s,adjustable | |||
take-up and payoff tensile | 0~10N,adjustable | |||
interface | Input switched 3-pole socket,tethered cable output XT60 connector | |||
Button and switch | High-voltage on/off button,cable forced retraction button,back up battery button | |||
Protection level | IPx4 | |||
Size | D360×W180×H260±0.5mm,excluding foot pads and handles | |||
Weight | 8.5±0.2kg,excluding tethered cable | |||
Tethered cable | Material | Silver plated lightweight high-temperature resistant aviation wire,lightweight high-temperature resistant sheath. | ||
Current | 3~5A | |||
DC resistance | 10.5±0.2Ω,100m@20ºCloop | |||
Resistance tensile strength | ≥20kg,resistant to repeated reaction and release times≥500 | |||
Insulation strength | ≥3500Vdc,1min, no breakdown | |||
Cable length | standard equipment 55m,optional 110m | |||
Outer diameter | 2.3±0.1mm | |||
Weight | 10±0.5g/m | |||
Air module | Input voltage | 580~810Vdc wide range input | ||
Output voltage | 25Vdc±1% or 50Vdc±1%,constant voltage output,support voltage customization | |||
Output power | ≥2000W(rated long-term output),≥2500W(peak value≮10s) | |||
Protection function | Input over voltage,under voltage protection,output over voltage,over current,short circuit,and over temperature protection | |||
Isolation voltage | ≥3000V(Vin-Vout),1min,Current leakage 5mA,no breakdown,flying arc and corona phenomena | |||
Installation method | Pre-mounted lugs, screwed in | |||
Heat dissipation | External fan for active cooling, reserved air ducts for forced air cooling | |||
Interface | Input XT60,output XT90×2 | |||
Protection level | IP54 | |||
Size | 145×60×42±0.5mm,excluding mounting lugs and connectors | |||
Weight | 510±10g,excluding outer connector and wire | |||
packages | Size | 550×420×260±5mm(backpack size),600×450×300±5mm(Carton Size) | ||
Weight | 14.5±0.5kg,including ground power module,air module,Annexes and documents |